| Voltage range | 80-300V |
| Current | 100A |
| Supply terminals | N,L |
It will automatically reinstate power once the voltage returns to a normal range, eliminating the need for manual reset. This ensures round-the-clock protection for household appliances and elevates the safety standard for end users.
| Voltage range | 80-300V |
| Current | 100A |
| Supply terminals | N,L |
| Rated supply voltage | AC 220V |
| Rated frequency | 50/60Hz |
| >U setting range | 130-300V |
| 80-210V | |
| Voltage hysteresis | 5V |
| Overvoltage trip delay | 0.5s |
| Voltage accuracy | <1% |
| Max.operating phase voltage | 350V |
| Max.operating current | 100A |
| Altitude | ≤200m |
| Ambient temperature | -25°℃~+50℃ |
| Permissable relative humidity | ≤50% at 40℃(without condensation) |
| Storage temperature | -25℃~+55℃ |

We provide customised solutions for professional circuit protection.